Henan fast direct method for boiler efficiency company was established in 1998, since its inception, has always insisted on doing clean and environmentally friendly gas-fired boiler. As of today, already has 108 self-patented technology, whether it is technology or burning boiler manufacturing, are all very advanced technology at home and abroad, more than 15% higher than the efficiency of conventional gas boilers, energy-saving effect is more significant.

The difference between hot water and steam direct method for boiler efficiencys of the boiler as a heat medium for air conditioning, heaters, low temperature oven drying equipment, textile and the hot water tank is heated by a variety of low-temperature, heat transfer and air-conditioning coil equipment. Hot water as a heat medium has the following advantages: 1. Generally the lower the heat medium water temperature of the heat medium, and large temperature difference between the flue gas, boiler exhaust gas temperature is relatively low, and thus higher boiler efficiency. 2. Closed hot water supply system small amount of water and sewage rate is much smaller than the steam boiler, waste water is also smaller. And lower boiler water quality requirements, less the cost of water treatment. 3. The specific heat capacity of water is large, a large hot water system capacity, strong heat storage capacity. When the thermal conditions or hydraulic failure condition a short time, without significantly heating conditions cause large fluctuations. 4. pump hot water heating system can be used for long-distance transportation, a small heat loss, heating large radius, to adapt to the requirements of urban planning central heating. The hot water temperature is low, less heat transfer coefficient, thermal efficiency is relatively low as the heat medium heating major drawback. Present predominantly of boiler steam boiler, steam as a heat medium main advantages are: a low cost, wide adaptability, can meet the heat requirements of the various users have different requirements for temperature and pressure simultaneously; 2 nontoxic. directly heating food, even if leaking would not harm the environment; 3 high steam temperature, a large latent heat of vaporization, the heat transfer area can be reduced relative to the hot water device, reduce costs; 4 hot inert small, heat faster when the steam supply, the cold disappear just as quickly when the steam stop. Since the heating medium steam condensate recovery is difficult, resulting in waste and water latent heat. Even with condensate recovery, condensate recovery in the process, because water easily dissolved oxygen and other impurities, but also easy to cause harm to the boiler. Oxygen to the water, salt and other impurities cause boiler fouling, corrosion and other problems affecting the safety and energy efficiency of the boiler.

Since more than six months since the direct method for boiler efficiency equipment, heating and hot water supply well, our technical staff also view real-time remote monitoring and control through the use of the boiler to the scene, Baiyun Quan Lake hotel management staff related to our technical staff gave very great encouragement and affirmation. --customer feedback

There economizer gas pipe on the direct method for boiler efficiency, the amount of wear and if it has reached thirty percent of the wall thickness, it is necessary to replace. There will replace Similarly superheater, reheater water wall tube, wall thickness abrasion to reach 25 percent.

direct method in calculating oil fired boiler efficiency

2020-3-18·Calculate industrial boiler efficiency Thailand. 2019-4-26·When buying boilers, many customers are concerned about boiler efficiency and boiler price. So how do we calculate the boiler efficiency? In actual practice, two methods are commonly used to find out boiler efficiency, namely direct method and indirect method of efficiency calculation.

Efficiency Improvement Opportunity in Boiler Without

2020-4-1·Boiler efficiency 77.8% 81.35% Table 4: Efficiency calculated by Direct and Indirect Method . Boiler efficiency AFBC (Atmospheric Fluidised Bed CFBC (Circulating Fluidised Bed Combustion) 80.58% 83.94% Indirect Method 77.8% 81.35% . 6. Discussion . As GCV of the coal is increases efficiency

Boiler efficiency analysis using direct method - IEEE

Boiler efficiency analysis using direct method Abstract: Real-time data of boiler thermal efficiency can really reflect the boiler operation condition, heat generation and heat loss. Performance of the boiler, like efficiency and evaporation ratio reduces with time, due to poor combustion, heat transfer fouling and poor operation and maintenance.

Chapter 4.1: Boiler Short type questions - Knowledge

2017-3-15·Chapter 4.1: Boiler Short type questions 1. In the absence of steam flow meter, suggest a method by which steam quantity can be assessed in a boiler. Ans. The feed water flow into the boiler can be used as an effective tool to quantify the steam flow rate from a boiler.

(PDF) A CASE STUDY FOR CALCULATION OF BOILER

There are two methods to determine boiler efficiency: direct method and indirect method. In this study, the efficiency of a fluidized bed boiler having a steam production capacity of 462000 kg/h

How can we calculate the efficiency of a boiler of a

Boiler efficiency is nothing but total absorption of heat against total input heat. Boiler value differs from type to type, for instance. In order to calculate the Boiler efficiency use the below formula 1. Direct method to calculate the Boiler e

Calculator: Boiler Efficiency | TLV - A Steam Specialist

2020-1-30·TLV CORPORATION is a proud member of the Fluid Controls Institute (FCI), a non-profit association of fluid control equipment manufacturers. FCI has distinguished itself in the technical advancement of the fluid control industry through the development of standards to promote the production of higher quality, more useful products.

Direct Method boiler efficiency 1 - ASKPOWERPLANT

2020-4-28·Direct Method boiler efficiency 1. Download the PDF file . Direct Method boiler efficiency 1. Facebook Comments. joginder chauhan. Heii all power engineers myself joginder chauhan . i am the founder of my website i am also a power engineer and having the more than 5 year experience in the field of power sectors during

Improving Energy Efficiency of Boiler Systems

2015-8-5·There are two methods of assessing boiler efficiency; 1. Input output or direct method, and 2. Heat loss or indirect method. Direct Method for Calculating Boiler Efficiency Direct method compares the energy gain of the working fluid (water and steam) to the energy content of the fuel.

Performance evaluation of industrial boiler by heat loss

2017-4-29·Performance evaluation of industrial boiler by heat loss method. So finally Boiler Efficiency by indirect method is Gujarat place is performed using the heat loss analysis for the performance evaluation of boiler house. Direct heat loss method is carried out in the boiler house which will give idea about the losses at different stages

Boiler efficiency analysis using direct method

Real-time data of boiler thermal efficiency can really reflect the boiler operation condition, heat generation and heat loss. Performance of the boiler, like efficiency and evaporation ratio reduces with time, due to poor combustion, heat transfer fouling and poor operation and maintenance. Boiler efficiency can be also useful in analysis of boiler and can also be used in predictive

Boiler efficiency by loss Method - LinkedIn SlideShare

Efficiency Calculations Standards Standard Applied :- ASME Standard PTC 4.1 IS 8753: Indian Standard for Boiler Efficiency Testing British standards, BS845: 1987 5. The Indirect Method Testing/Loss Method L1. Loss due to dry flue gas (sensible heat) L2. Loss due to hydrogen in fuel (H2) L3. Loss due to moisture in fuel (H2O) L4.

Boiler Efficiency Improvement amp; Heat Loss Explained

Direct efficiency This is also recognized as the input-output method because it requires only the valuable output like steam and the heat input for estimating the boiler efficiency. This efficiency can be calculated using the formula: η= (Energy output)/(Energy input) X 100. To measure boiler efficiency in this way, we divide the total energy

A Research of Simplified Method in Boiler Efficiency

The test of boiler efficiency is an effective way to identify boiler problems and improve its efficiency. Until 2008, the total number of using industrial boilers has been amounted to 578200 units. The traditional method to test boiler efficiency is time consuming and expensive, and the test of boiler efficiency needs ultimate analysis of fuel.

4.1 Boiler_

2012-9-19·Bureau of Energy Efficiency 9 1. Energy Performance Assessment of Boilers 1.7.4 Boiler Efficiency by Indirect Method: Calculation Procedure and Formula In order to calculate the boiler efficiency by indirect method, all the losses that occur in the boiler must be